Home > Blog > Content

Precautions for hydraulic oil temperature

Nov 17, 2024

 

Yantai Fanghe Machinery Equipment Co., Ltd. was established in December 2016. The company's business projects: design, production and sales of various mining machinery and supporting equipment; production and sales of riveted and welded parts such as buckets, arms, and frames of scrapers; processing and sales of various mining machinery accessories and parts; modification and overhaul services for various mining vehicles and engineering vehicles.

1. Hazards of excessive hydraulic oil temperature

① The viscosity, volumetric efficiency and working efficiency of the hydraulic oil and the hydraulic system are all reduced, leakage increases, and even mechanical equipment cannot work normally.

② The parts of the hydraulic system expand due to overheating, destroying the original normal matching clearance of the relatively moving parts, resulting in increased friction resistance and easy jamming of the hydraulic valve. At the same time, the lubricating oil film becomes thinner and the mechanical wear increases. As a result, the precision matching surfaces of pumps, valves, motors, etc. are worn out prematurely, causing them to fail or be scrapped.

③ Accelerate the aging and deterioration of rubber seals, shorten their life, and even lose their sealing performance, causing serious leakage in the hydraulic system.
④ The vaporization of oil and evaporation of water can easily cause pitting of hydraulic components; the oxidation of oil to form colloidal deposits can easily clog the small holes in the oil filter and hydraulic valve, making the hydraulic system unable to work normally.
Therefore, too high a hydraulic oil temperature will seriously affect the normal use of the machine, reduce the service life of hydraulic components, and increase the maintenance cost of construction machinery.
2. Causes and preventive measures of too high a hydraulic oil temperature
(1) Improper oil selection
The brand, quality and viscosity grade of the oil do not meet the requirements, or different grades of hydraulic oil are mixed, resulting in a too low or too high viscosity index of the hydraulic oil. If the viscosity of the oil is too high, the power loss will increase and the oil temperature will rise; if the viscosity is too low, the leakage will increase and the oil temperature will rise.
Preventive measures: The oil should be selected according to the brand recommended by the manufacturer and the working environment and temperature factors of the machine. For some machines with special requirements, special hydraulic oil should be selected; when the hydraulic components and systems are inconvenient to maintain, good performance anti-wear hydraulic oil should be selected.
(2) Severe pollution
The construction site environment is harsh. As the machine works longer, impurities and dirt are easily mixed into the oil. The contaminated hydraulic oil enters the matching gap of the pump, motor and valve, which will scratch and damage the precision and roughness of the matching surface, increase leakage and increase oil temperature.
Preventive measures: Generally, the oil should be changed after more than 1,000 hours of cumulative work. When changing the oil, pay attention to not only draining the old oil in the oil tank, but also replacing the old oil in the entire system pipeline and working circuit; when refueling, it is best to use a filter with a mesh size of 120 or more, and add enough oil as required to ensure that the oil has sufficient circulation and cooling conditions. In the event of a sudden failure caused by hydraulic oil contamination, be sure to filter or replace the hydraulic system oil. For example, a YZT14G roller had a hydraulic oil temperature that was too high and the vibration force was insufficient; inspection found that the hydraulic oil was milky white, had deteriorated, and the viscosity decreased. After replacing the hydraulic oil, the roller returned to normal operation.
(3) The oil level in the hydraulic oil tank is too low
If the amount of oil in the hydraulic oil tank is too little, the hydraulic system will not have enough flow to carry away the heat it generates, resulting in an increase in oil temperature.
Preventive measures: During actual operation and maintenance, strictly abide by the regulations on hydraulic oil level in the operating procedures. For example, a PC2003 hydraulic excavator had a hydraulic oil temperature failure after working for a period of time. After checking the hydraulic oil tank, it was found that the oil level was much lower than the specified value. Due to the excessive lack of oil in the hydraulic system, the hydraulic oil circulated too quickly and failed to fully cool down, resulting in an increase in oil temperature. After adding enough hydraulic oil as required, the hydraulic oil temperature immediately dropped to the normal range.
(4) Air mixed in the hydraulic system
Air mixed in the hydraulic oil will escape from the oil in the low-pressure area and form bubbles. When it moves to the high-pressure area, these bubbles will be crushed by the high-pressure oil, and will be compressed sharply and release a large amount of heat, causing the oil temperature to rise.
Preventive measures: Frequently check the sealing of the oil inlet pipe interface to prevent air from entering; at the same time, exhaust the air in the system after each oil change. For example, the hydraulic oil temperature of a PY184 grader was too high, accompanied by hydraulic noise. Inspection revealed that the hydraulic pump oil inlet connection hose was slightly damaged, sucking in air, causing the oil temperature to be too high. After replacing the hose, the grader ran well.

(5) Oil filter blockage

When abrasive particles, impurities and dust pass through the oil filter, they will be adsorbed on the filter element of the oil filter, causing the oil absorption resistance and energy consumption to increase, causing the oil temperature to rise.

Preventive measures: Clean and replace the oil filter regularly. For oil filters with blockage indicators, the filter element should be cleaned or replaced according to the indication; the performance, structure and validity period of the filter element must meet its use requirements. For example, the oil temperature alarm of a TY220 bulldozer sounded continuously during operation. At the same time, oil smoke and burning smell of oil were found at the torque converter, and the oil level in the steering tank was low. The inspection results showed that the fault was caused by the blockage of the oil suction filter of the torque converter return pump. Because the filter was full of sediment, the oil leaked from the torque converter could not be pumped back to the steering tank in time. As the sediment accumulated, the resistance of the torque converter increased, and the heat generated by friction increased, which eventually led to the oil temperature rising too fast. After cleaning the filter, the oil temperature returned to normal. For another example, the hydraulic transmission system of a CATD8N crawler bulldozer issued a high temperature alarm and there was an abnormal sound in the transmission part. The oil filter was disassembled to check the filter element, and it was found that it contained a large amount of powdery dirt. After replacing the filter element, the fault disappeared.

(6) The hydraulic oil cooling circulation system is not working properly.

Usually, a water-cooled or air-cooled oil cooler is used to force the oil temperature of the hydraulic system to cool down. Water-cooled coolers will reduce their heat dissipation coefficient due to dirty fins or poor water circulation; air-cooled coolers will clog the gaps of the cooler fins due to excessive oil pollution, making it difficult for the fan to dissipate heat, resulting in increased oil temperature.
Preventive measures: Regularly check and maintain the hydraulic oil cooling circulation system. Once a fault is found, it must be stopped immediately to eliminate it. For example, a CPCD60D hydraulic transmission forklift had insufficient torque converter driving force and heavy steering wheel after working for a period of time (the hydraulic transmission and power steering share a pump); after several inspections, it was found that the air-cooled oil cooler's ventilation holes were blocked, causing the oil temperature to be too high. After unblocking, the fault was eliminated. For another example, a K-702 loader cooler started working for less than 3 hours, and the torque converter oil temperature alarm indicator on the instrument panel flashed, indicating that the hydraulic oil temperature was too high. First check the oil quantity and oil quality, and the result is that the oil quantity is sufficient and the oil quality is good; then check the oil filter, which is not dirty; then check the cooler, and find that the sludge has blocked part of the cooler and oil holes. After cleaning the cooler, everything is normal.

(7) Serious wear of parts

The gears and pump bodies and side plates of gear pumps, the cylinder bodies and distribution plates, cylinder body holes and plungers of plunger pumps and motors, and the valve stems and valve bodies of reversing valves are all sealed by gaps. The wear of these components will cause increased internal leakage and increased oil temperature.

Preventive measures: Timely repair or replace parts with excessive wear. According to statistics, under normal circumstances, after five or six years of operation of imported hydraulic pumps and motors, and two or three years of operation of domestic products, their wear is already quite serious and must be repaired in time. Otherwise, the machine will work basically normally when cold, but after working for 1-2 hours, the movement speed of each mechanism of the system will obviously slow down, and it is necessary to stop the machine and wait for the oil temperature to drop before continuing to work. For example, after a WY160 hydraulic excavator had the above fault, the working pressure of each mechanism was significantly low after testing, and it was suspected that it was caused by the wear of the main safety valve or main pump. First, the main safety valve was disassembled and inspected, and no abnormal phenomenon was found; then the main pump was disassembled and inspected, and it was found that the spherical surface of the distribution plate was seriously worn. After grinding the distribution plate, it was reassembled and its clearance was adjusted, and the installation and operation were good. For another example, a ZL50 loader moved slowly and weakly. After testing, the system pressure was low, and the gear pump felt very hot when touched. It was suspected that the gear pump was internally worn and leaked. After disassembly and inspection, it was found that the clearance between the gear pump side plate and the gear end face was out of tolerance. After replacing the gear pump, the problem was solved.

(8) Excessive ambient temperature

Excessive ambient temperature and long-term high-load use will cause the oil temperature to be too high.

Preventive measures: Avoid long-term continuous high-load operation; if the oil temperature is too high, the equipment can be rotated without load for about 10 minutes, and then work after the oil temperature drops.

Fanghe Machinery will help you have a bright future! Welcome new and old customers to inquire, guide, negotiate and cooperate!

Send Inquiry